cat 307 excavator controls

  • Safety near power lines - Pacific Gas and Electric Company

    WebWorking Near Power Lines A spotter must be present Must have a clear view of the power line and the equipment operator, and be able to immediately inform the operator of any danger. A dedicated power line spotter may be required to watch distance to power lines.

    Learn More
  • Construction Safety | ComEd - An Exelon Company

    WebAlways assume power lines are live. This applies to power lines on utility poles as well as those entering your home or buildings. Even momentary contact can injure or kill. Always keep yourself, your equipment, and anything you carry at least 10 feet from power lines.

    Learn More
  • Power line safety tips - Texas Department of Insurance

    WebYou should clearly mark the location of power lines and the minimum clearance area with signs that say Danger: Overhead Power Lines, Buried Power Lines, Buried Natural Gas Lines or Look Up and Live. Barricade the area where materials or equipment are to be moved and supervise the area, restricting entry to personnel engaged in the work.

    Learn More
  • IOSH's Safety Training Presentations - Occupational Safety …

    Webnear power lines in 29 CFR, 1926.550(a) (15)-Cranes and Derricks.1 This subsection covers non-energized power lines; mandates minimum clearance between power lines and crane or load, in operation and in transit; requires the designation of a signal person or spotter to observe clearance and give timely warning; mentions the use of cage

    Learn More
  • Safety Around Power Lines – Water Well Journal

    WebWorking near energized conductors Overhead power lines have a limit of approach; a safe distance workers must keep while working. Only trained workers may operate up to the limit of approach. It's important everyone on the jobsite fully understands the hazards when working close to energized conductors.

    Learn More
  • 1926.600 - Equipment. - Occupational Safety and Health Administration

    WebAll equipment covered by this subpart shall comply with the following requirements when working or being moved in the vicinity of power lines or energized transmitters, except where electrical distribution and transmission lines have been deenergized and visibly grounded at point of work or where insulating barriers, not a part of or an …

    Learn More
  • Minimum approach distances to insulated power lines by …

    WebJul 18, 2001 · Answer: Section 1926.451 (f) (6) of the scaffold standard states that scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than the applicable minimum approach distance table in the scaffold standard.

    Learn More
  • SAFETY LETTER - Arizona Public Service

    WebOct 14, 2016 · Operate cranes only if trained in safe operating procedures and OSHA regulations. Operate cranes at a slower-than-normal rate in power line areas. Use caution when moving over uneven ground that could cause the crane to weave or bob into power lines. Use caution near long spans of overhead power lines, since wind can cause the …

    Learn More
  • General guide for working in the vicinity of overhead and …

    WebSep 27, 2016 · It's a well-known fact that power lines and cranes do not mix. Between 1992 and 2006, 102 construction workers died as a result of crane-related, overhead power line electrocutions. To help reduce these needless deaths, in 2010, OSHA spelled out the steps necessary for cranes to work around power lines in the updated Cranes and Derricks in …

    Learn More
  • General guide for working in the vicinity of overhead and …

    WebJul 11, 2016 · Very recently, two PAR Electric employees in Missouri were seriously injured from electric shock as they worked near a 69kV power line. They were holding a pole while a crane was moving into position when a gust of wind blew their pole into the energized line. Both men were airlifted to different hospitals for treatment. Tree Trimmer Gets Shocked

    Learn More
  • Electrocutions spur MSHA safety alert about overhead power lines

    WebWhen the worker is elevated, the safe distance between the work and energized overhead power lines is shortened. Erecting scaffolds, relocating them, and working on the platform itself all require workers to maintain safe distances from power lines.

    Learn More
  • HEAVY EQUIPMENT NEAR OVERHEAD POWER LINES? …

    WebWhile only 3.8% of nonfatal electrical injuries involved contact with overhead power lines; such contact caused 41% of all electrical fatalities. So, contact with overhead power lines is much more likely to be fatal than many other types of electrical accidents. Common overhead power-line contact incidents involve operators and nearby workers

    Learn More
  • Working Safely Around the Lines - Hydro One

    WebIf you work with dump trucks, bucket trucks, cranes, excavators, backhoes, ladders, or other equipment with a long reach, chances are you are working dangerously close to overhead or underground power lines. Power lines as well as the surrounding air space which insulates the line can be hazardous.

    Learn More
  • Working Around Power Lines & How You Can Avoid an Accident

    WebWorking with or near power lines can expose workers to electrical hazards. The first step in preventing injuries is Should equipment contact a power line, call 911 and the local utility company. o If no one is in danger from fire or power-line strikes, move the equipment away from the power line, if possible. If the equipment is not on fire and

    Learn More
  • CONTRACTOR SAFETY HANDBOOK - Alliant Energy

    WebFeb 24, 2023 · Arlington, VA — Recent deaths involving miners working near overhead power lines have prompted the Mine Safety and Health Administration to issue a safety alert. In two separate incidents on Jan. 27 and Feb. 6, three miners were electrocuted after their trucks came into contact with overhead power lines, MSHA reports.

    Learn More
  • Protection While Working Around Overhead Power Lines …

    WebAug 12, 2021 · If working on power lines, ensure that the lines have been de-energized and grounded by the owner or operator of the lines. Other protective measures like guarding or insulating the lines help prevent accidental contact. Employees unqualified to work with electricity, as well as mechanical equipment, should

    Learn More
  • Overhead Powerline Safety - Electrical Safety Foundation International

    WebOverhead Powerline Safety Between 2011 and 2020, 39% of all electrically related workplace fatalities were caused by overhead power lines. In the majority of these cases, fatalities occurred in occupations with little to no electrical safety training. So when you're on a job site, remember to always look up, always – it can save your life.

    Learn More
  • Working Around Overhead Power Line Tips - reagansafety.com

    Weblines during the time you will be working near them. WORKING WITH TOOLS & EQUIPMENT If the lines cannot be shut down and/or insulation applied, a minimum safe distance of 10 feet must be established. Have a brief job site meeting to discuss the planned work as it relates to the power lines. Discuss topics such as the use of long-handled …

    Learn More
  • Minimum approach distances to insulated power lines by …

    WebJul 18, 2001 · Answer: Section 1926.451 (f) (6) of the scaffold standard states that scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than the applicable minimum approach distance table in the scaffold standard.

    Learn More
  • Working near energized conductors - WorkSafeBC

    WebThe minimum safe distance for equipment operating in proximity to energized power lines that contain up to 50,000 volts is: C. 10 feet Any overhead power line should be considered energized unless the entity owning or operating the electrical utility supplying the line certifies that it is

    Learn More